014-CEF0R01 Yaskawa014CEF0R01

014-CEF0R01 - CPUs | CPUs STEP7 programmable, standard; Order no. : 014-CEF0R01; Type : CPU 014; Features : Powered by SPEED7 Work memory [KB]: 128...256; Interface [2x RJ45]: active Ethernet PG/OP communication with DHCP support, switch, ModbusTCP master/slave, openCommunication, I-Device, PROFINET IO controller (8 devices); Interface [2x RS485]: MPI, PtP: ASCII, STX/ETX, 3964(R), USS master, Modbus master/slave Optional: PROFIBUS master/slave Web server SD card slot with locking, up to 64 expansion modules, configurable with SPEED7 Studio, SIMATIC Manager and TIA Portal; Power supply (rated value) : DC 24 V; Power supply (permitted range) : DC 20.4...28.8 V; Reverse polarity protection : Current consumption (no-load operation) : 120 mA; Current consumption (rated value) : 1 A; Inrush current : 3 A; I²t : 0.1 A²s; Max. current drain at backplane bus : 3 A; Max. current drain load supply : 10 A; Power loss : 6 W; Load memory, integrated : 256 KB; Load memory, maximum : 256 KB; Work memory, integrated : 128 KB; Work memory, maximal : 256 KB; Memory divided in 50% program / 50% data : Memory card slot : SD/MMC-Card with max. 2 GB; Racks, max. : 5; Modules per rack, max. : total max. 64 minus number line extensions; Number of integrated DP master : 1; Operable function modules : 64; Operable communication modules PtP : 64; Status display : yes; Interrupts : no; Process alarm : no; Diagnostic interrupt : no; Diagnostic functions : yes; Diagnostics information read-out : possible; Supply voltage display : green LED; Group error display : red SF LED; Channel error display : none; Bit instructions, min. : 0.02 µs; Word instruction, min. : 0.02 µs; Double integer arithmetic, min. : 0.02 µs; Floating-point arithmetic, min. : 0.12 µs; Number of S7 counters : 512; S7 counter remanence : adjustable 0 up to 512; S7 counter remanence adjustable : C0 .. C7; Number of S7 times : 512; S7 times remanence : adjustable 0 up to 512; S7 times remanence adjustable : not retentive; Number of flags : 8192 Byte; Bit memories retentive characteristic adjustable : adjustable 0 up to 8192; Bit memories retentive characteristic preset : MB0 .. MB15; Number of data blocks : 1024; Max. data blocks size : 64 KB; Number range DBs : 1 ... 8191; Max. local data size per execution level : 4096 Byte; Max. local data size per block : 4096 Byte; Number of OBs : 22; Maximum OB size : 64 KB; Total number DBs, FBs, FCs : 1024; Number of FBs : 1024; Maximum FB size : 64 KB; Number range FBs : 0 ... 8191; Number of FCs : 1024; Maximum FC size : 64 KB; Number range FCs : 0 ... 8191; Maximum nesting depth per priority class : 16; Maximum nesting depth additional within an error OB : 4; Real-time clock buffered : Clock buffered period (min.) : 30 d; Type of buffering : Goldcap; Load time for 50% buffering period : 15 min; Load time for 100% buffering period : 1 h; Accuracy (max. deviation per day) : 10 s; Number of operating hours counter : 8; Clock synchronization : Synchronization via MPI : Master/Slave; Synchronization via Ethernet (NTP) : no; Input I/O address area : 2048 Byte; Output I/O address area : 2048 Byte; Process image adjustable : Input process image preset : 128 Byte; Output process image preset : 128 Byte; Input process image maximal : 2048 Byte; Output process image maximal : 2048 Byte; Digital inputs : 16384; Digital outputs : 16384; Digital inputs central : 512; Digital outputs central : 512; Analog inputs : 1024; Analog outputs : 1024; Analog inputs, central : 256; Analog outputs, central : 256; PG/OP channel : Global data communication : Number of GD circuits, max. : 8; Size of GD packets, max. : 22 Byte; S7 basic communication : S7 basic communication, user data per job : 76 Byte; S7 communication : S7 communication as server : S7 communication, user data per job : 160 Byte; Number of connections, max. : 32; Type : X2; Type of interface : RS485; Connector : Sub-D, 9-pin, female; Electrically isolated : MPI : Point-to-point interface : 5V DC Power supply : max. 90mA, isolated; 24V DC Power supply : max. 100mA, non-isolated; Type : X3; Type of interface : RS485; Connector : Sub-D, 9-pin, female; Electrically isolated : MPI : DP master : optional; DP slave : optional; 5V DC Power supply : max. 90mA, isolated; 24V DC Power supply : max. 100mA, non-isolated; Number of connections, max. : 32; PG/OP channel : Routing : Global data communication : S7 basic communication : S7 communication : S7 communication as server : Transmission speed, min. : 19.2 kbit/s; Transmission speed, max. : 12 Mbit/s; Number of connections, max. : 32; PG/OP channel : Routing : S7 basic communication : S7 communication : S7 communication as server : Activation/deactivation of DP slaves : DPV 1 : Transmission speed, min. : 9.6 kbit/s; Transmission speed, max. : 12 Mbit/s; Number of DP slaves, max. : 124; Address range inputs, max. : 2 KB; Address range outputs, max. : 2 KB; User data inputs per slave, max. : 244 Byte; User data outputs per slave, max. : 244 Byte; Number of connections, max. : 32; PG/OP channel : Routing : S7 communication : S7 communication as server : DPV 1 : Transmission speed, min. : 9.6 kbit/s; Transmission speed, max. : 12 Mbit/s; Transfer memory inputs, max. : 244 Byte; Transfer memory outputs, max. : 244 Byte; Address areas, max. : 32; User data per address area, max. : 32 Byte; Type : X1; Type of interface : Ethernet 10/100 MBit Switch; Connector : RJ45; Electrically isolated : PG/OP channel : Number of connections, max. : 4; Productive connections : PtP communication : Interface isolated : RS485 interface : Connector : Sub-D, 9-pin, female; Transmission speed, min. : 1200 bit/s; Transmission speed, max. : 115.5 kbit/s; Cable length, max. : 500 m; ASCII protocol : STX/ETX protocol : 3964(R) protocol : USS master protocol : Modbus master protocol : Modbus slave protocol : Conformance Class : PROFINET IO; Number of  PN IO devices : 8; Shared Device supported : MRP Client supported : Number of PN IO lines : 1; Address range inputs, max. : 2 KB; Address range outputs, max. : 2 KB; Transmiting clock : 1 ms; Update time : 1 ms .. 512 ms; Parallel operation as controller and I-Device : I/O Data range, max. : 768 Byte; Update time : 1 ms .. 512 ms; Protocols : ICMPDCPLLDP / SNMPNTP; Web based diagnosis : Number of productive connections via PG/OP, max. : 4; Number of productive connections by Siemens NetPro, max. : 4; S7 connections : BSEND, BRCV, GET, PUT, Connection of active and passive data handling; User data per S7 connection, max. : 64 KB; TCP-connections : FETCH PASSIV, WRITE PASSIV, Connection of passive data handling; User data per TCP connection, max. : 8 KB; ISO on TCP connections (RFC 1006) : FETCH PASSIV, WRITE PASSIV, Connection of passive data handling; User data per ISO connection, max. : 8 KB; Number of configurable connections, max. : 4; ISO on TCP connections (RFC 1006) : TSEND, TRCV, TCON, TDISCON; User data per ISO on TCP connection, max. : 32 KB; TCP-Connections native : TSEND, TRCV, TCON, TDISCON; User data per native TCP connection, max. : 32 KB; User data per ad hoc TCP connection, max. : 1460 Byte; UDP-connections : TUSEND, TURCV; User data per UDP connection, max. : 1472 KB; WebVisu is supported : Max. number of connections WebVisu : 4; WebVisu supports HTTP : WebVisu supports HTTPS : Material : PPE / PPE GF10; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 131.5 mm x 109 mm x 83 mm; Net weight : 290 g; Weight including accessories : 290 g; Gross weight : 325 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes; KC certification : yes