013-CCF0R00 Yaskawa013CCF0R00

013-CCF0R00 - CPUs | CPUs STEP7 programmable, C class; Order no. : 013-CCF0R00; Type : CPU 013C; Features : Powered by SPEED7 Work memory [KB]: 64...128 Onboard 16x DI / 12x DO / 2x AI [voltage 0...10 V] ] / 4x Counter / 2x [PWM/Pulse Train]; Interface [2x RJ45]: active Ethernet PG/OP communication with DHCP support, switch, ModbusTCP master/slave, openCommunication, I-Device, PROFINET IO controller (8 devices); Interface [RS485]: MPI, PtP: ASCII, STX/ETX, 3964 (R), USS master, Modbus master/slave Optional: PROFIBUS master/slave Web server SD card slot with locking, up to 64 expansion modules, configurable with SPEED7 Studio, SIMATIC Manager and TIA Portal; Power supply (rated value) : DC 24 V; Power supply (permitted range) : DC 20.4...28.8 V; Reverse polarity protection : Current consumption (no-load operation) : 120 mA; Current consumption (rated value) : 360 mA; Inrush current : 3 A; I²t : 0.1 A²s; Max. current drain at backplane bus : 1 A; Max. current drain load supply : 6 A; Power loss : 7 W; Number of inputs : 16; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 25 mA; Rated value : DC 24 V; Input voltage for signal "0" : DC 0...5 V; Input voltage for signal "1" : DC 15...28.8 V; Signal logic input : Sinking input; Input current for signal "1" : 3 mA; Connection of Two-Wire-BEROs possible : Max. permissible BERO quiescent current : 0.5 mA; Input delay of "0" to "1" : 3 µs – 15 ms / 0.5 ms – 15 ms; Input delay of "1" to "0" : 3 µs – 15 ms / 0.5 ms – 15 ms; Number of simultaneously utilizable inputs horizontal configuration : 16; Number of simultaneously utilizable inputs vertical configuration : 16; Input characteristic curve : IEC 61131-2, type 1; Initial data size : 16 Bit; Number of outputs : 12; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 20 mA; Total current per group, horizontal configuration, 40°C : 6 A; Total current per group, horizontal configuration, 60°C : 6 A; Total current per group, vertical configuration : 6 A; Output voltage signal "1" at min. current : L+ (-0.8 V); Output voltage signal "1" at max. current : L+ (-0.8 V); Output current at signal "1", rated value : 0.5 A; Signal logic output : Sourcing output; Output current, permitted range to 40°C : 5 mA to 0.6 A; Output current, permitted range to 60°C : 5 mA to 0.6 A; Output current at signal "0" max. (residual current) : 0.5 mA; Output delay of "0" to "1" : 2 µs / 30 µs; Output delay of "1" to "0" : 3 µs / 175 µs; Lamp load : 10 W; Parallel switching of outputs for redundant control of a load : not possible; Parallel switching of outputs for increased power : not possible; Actuation of digital input : Switching frequency with resistive load : max. 1000 Hz; Switching frequency with inductive load : max. 0.5 Hz; Switching frequency on lamp load : max. 10 Hz; Internal limitation of inductive shut-off voltage : L+ (-45 V); Short-circuit protection of output : yes, electronic; Trigger level : 1 A; Output data size : 12 Bit; Number of inputs : 2; Cable length, shielded : 200 m; Voltage inputs : Min. input resistance (voltage range) : 100 kΩ; Input voltage ranges : 0 V ... +10 V; Operational limit of voltage ranges : +/-3.5%; Basic error limit voltage ranges : +/-3.0%; Destruction limit voltage : max. 30V; Resolution in bit : 12; Measurement principle : successive approximation; Basic conversion time : 0.5 ms; Noise suppression for frequency : 40 dB; Initial data size : 4 Byte; Number of counters : 4; Counter width : 32 Bit; Maximum input frequency : 100 kHz; Maximum count frequency : 400 kHz; Mode incremental encoder : Mode pulse / direction : Mode pulse : Mode frequency counter : Mode period measurement : Gate input available : Latch input available : Counter output available : Load memory, integrated : 128 KB; Load memory, maximum : 128 KB; Work memory, integrated : 64 KB; Work memory, maximal : 128 KB; Memory divided in 50% program / 50% data : Memory card slot : SD/MMC-Card with max. 2 GB; Racks, max. : 5; Modules per rack, max. : total max. 64 minus number line extensions; Operable function modules : 64; Operable communication modules PtP : 64; Status display : yes; Interrupts : yes; Process alarm : yes; Diagnostic interrupt : yes; Diagnostic functions : yes, parameterizable; Diagnostics information read-out : possible; Supply voltage display : green LED; Group error display : red SF LED; Channel error display : red LED per group; Between channels : Between channels of groups to : 16; Between channels and backplane bus : Max. potential difference between circuits : DC 75 V/ AC 50 V; Insulation tested with : DC 500 V; Bit instructions, min. : 0.02 µs; Word instruction, min. : 0.02 µs; Double integer arithmetic, min. : 0.02 µs; Floating-point arithmetic, min. : 0.12 µs; Number of S7 counters : 512; S7 counter remanence : adjustable 0 up to 256; S7 counter remanence adjustable : C0 .. C7; Number of S7 times : 512; S7 times remanence : adjustable 0 up to 256; S7 times remanence adjustable : not retentive; Number of flags : 8192 Byte; Bit memories retentive characteristic adjustable : adjustable 0 up to 256; Bit memories retentive characteristic preset : MB0 .. MB15; Number of data blocks : 1024; Max. data blocks size : 64 KB; Max. local data size per execution level : 4096 Byte; Number of OBs : 22; Number of FBs : 1024; Number of FCs : 1024; Maximum nesting depth per priority class : 16; Maximum nesting depth additional within an error OB : 4; Real-time clock buffered : Clock buffered period (min.) : 30 d; Accuracy (max. deviation per day) : 10 s; Number of operating hours counter : 8; Clock synchronization : Synchronization via MPI : Master/Slave; Synchronization via Ethernet (NTP) : no; Input I/O address area : 2048 Byte; Output I/O address area : 2048 Byte; Input process image maximal : 2048 Byte; Output process image maximal : 2048 Byte; Digital inputs : 16224; Digital outputs : 16256; Digital inputs central : 528; Digital outputs central : 524; Integrated digital inputs : 16; Integrated digital outputs : 12; Analog inputs : 1015; Analog outputs : 1015; Analog inputs, central : 514; Analog outputs, central : 256; Integrated analog inputs : 2; Number of outputs : 1; Output voltage (typ) : L+ (-1.5 V); Output voltage (rated value) : 300 mA; Short-circuit protection : yes, electronic; Binding of potential : Power supply of PLC; PG/OP channel : Global data communication : Number of GD circuits, max. : 8; Size of GD packets, max. : 54 Byte; S7 basic communication : S7 basic communication, user data per job : 76 Byte; S7 communication : S7 communication as server : S7 communication, user data per job : 160 Byte; Number of connections, max. : 32; PWM channels : 2; PWM time basis : 1 µs / 0.1 ms / 1 ms; Period length : 50µs...65.535ms / 0.1...87ms / 1...87ms; Minimum pulse width : 0...0.5 * Period duration; Type of output : Highside; Type : X3; Type of interface : RS485; Connector : Sub-D, 9-pin, female; Electrically isolated : MPI : DP master : optional; DP slave : optional; Point-to-point interface : 5V DC Power supply : max. 90mA, isolated; 24V DC Power supply : max. 100mA, non-isolated; Number of connections, max. : 32; PG/OP channel : Routing : Global data communication : S7 basic communication : S7 communication : S7 communication as server : Transmission speed, min. : 19.2 kbit/s; Transmission speed, max. : 12 Mbit/s; Number of connections, max. : 32; PG/OP channel : Routing : S7 basic communication : S7 communication : S7 communication as server : Activation/deactivation of DP slaves : DPV 1 : Transmission speed, min. : 9.6 kbit/s; Transmission speed, max. : 12 Mbit/s; Number of DP slaves, max. : 32; Address range inputs, max. : 2 KB; Address range outputs, max. : 2 KB; User data inputs per slave, max. : 244 Byte; User data outputs per slave, max. : 244 Byte; Number of connections, max. : 32; PG/OP channel : Routing : S7 communication : S7 communication as server : DPV 1 : Transmission speed, min. : 9.6 kbit/s; Transmission speed, max. : 12 Mbit/s; Automatic detection of transmission speed : Transfer memory inputs, max. : 244 Byte; Transfer memory outputs, max. : 244 Byte; Address areas, max. : 32; User data per address area, max. : 32 Byte; Type : X1/X2; Type of interface : Ethernet 10/100 MBit Switch; Connector : 2 x RJ45; Electrically isolated : PG/OP channel : Number of connections, max. : 4; Productive connections : PtP communication : Interface isolated : RS485 interface : Connector : Sub-D, 9-pin, female; Transmission speed, min. : 1200 bit/s; Transmission speed, max. : 115.5 kbit/s; Cable length, max. : 500 m; ASCII protocol : STX/ETX protocol : 3964(R) protocol : USS master protocol : Modbus master protocol : Modbus slave protocol : Conformance Class : PROFINET IO; Number of  PN IO devices : 8; Shared Device supported : MRP Client supported : Number of PN IO lines : 1; Address range inputs, max. : 2 KB; Address range outputs, max. : 2 KB; Transmiting clock : 1 ms; Update time : 1 ms .. 512 ms; Parallel operation as controller and I-Device : I/O Data range, max. : 768 Byte; Update time : 1 ms .. 512 ms; Protocols : ICMPDCPLLDP / SNMPNTP; Web based diagnosis : Number of productive connections via PG/OP, max. : 2; Number of productive connections by Siemens NetPro, max. : 2; S7 connections : BSEND, BRCV, GET, PUT, Connection of active and passive data handling; User data per S7 connection, max. : 64 KB; TCP-connections : FETCH PASSIV, WRITE PASSIV, Connection of passive data handling; User data per TCP connection, max. : 8 KB; ISO on TCP connections (RFC 1006) : FETCH PASSIV, WRITE PASSIV, Connection of passive data handling; User data per ISO connection, max. : 8 KB; Number of configurable connections, max. : 2; ISO on TCP connections (RFC 1006) : TSEND, TRCV, TCON, TDISCON; User data per ISO on TCP connection, max. : 32 KB; TCP-Connections native : TSEND, TRCV, TCON, TDISCON; User data per native TCP connection, max. : 32 KB; User data per ad hoc TCP connection, max. : 1460 Byte; UDP-connections : TUSEND, TURCV; User data per UDP connection, max. : 1472 Byte; WebVisu is supported : Max. number of connections WebVisu : 4; WebVisu supports HTTP : WebVisu supports HTTPS : Material : PPE / PPE GF10; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 147 mm x 100 mm x 83 mm; Net weight : 320 g; Weight including accessories : 320 g; Gross weight : 355 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes; KC certification : yes