3WL1363-4AA47-1FA4-Z C01+C22+M06+M25+S05
SIEMENS ⍾ 3WL13634AA471FA4ZC01C22M06M25S05
Withdraw. non-aut. circuit-b. with guide frame 4-pole, size III, IEC In=6300A to 690V, AC50/60Hz Icu=100kA at 500V rear connection vertical without overcurrent release With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC C01= Mechanical switching cycle counter C22= Ready-to-close signaling M06= Motor drive, Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC M25= Switch-on solenoid 110-127 V AC/110-125 V DC, 100% on-load factor S05= Fortress locking device in Off position Disconnector condition Safe Off/disconnector function
Related in 3WL ⍾ Page 1
-
3WL1008-1AC30-4HA7
Withdrawable circuit breakers without guide frame 3-pole, frame size 0, IEC In=800A to 690V, 50/60Hz AC Icu=42kA at 415V Icu=42kA at 500V ETU350 electronic trip units LSI rotary co …
-
3WL1008-1AC32-4JA7-Z K52
+T30 Withdrawable circuit breakers with guide frame and PSS 3-pole, frame size 0, IEC In=800A to 690V, 50/60Hz AC Icu=42kA at 415V Icu=42kA at 500V ETU350 electronic trip units LSI rota …
-
3WL1010-2AB02-0AA0-Z A07
+S22 +T30 Fixed-mounted circuit breakers 3-pole, frame size 0, IEC In=1000A to 690V, 50/60Hz AC Icu=55kA at 415V Icu=50kA at 500V Icu=42kA at 690V ETU320 electronic trip units li rotary codi …
-
3WL1010-3AE32-0AA0-Z K50
+K52 +K53 +K55 +S23 +T30 Withdrawable circuit breakers with guide frame and PSS 3-pole, frame size 0, IEC In=1000A to 690V, 50/60Hz AC Icu=66kA at 415V Icu=50kA at 500V Icu=50kA at 690V ETU650 electronic t …
-
3WL1012-1AC32-4AA0
Withdrawable circuit breakers with guide frame and PSS 3-pole, frame size 0, IEC In=1250A to 690V, 50/60Hz AC Icu=42kA at 415V Icu=42kA at 500V ETU350 electronic trip units LSI rot …
-
3WL1012-2AB03-1AA8
Fixed-mounted circuit breakers 3-pole, frame size 0, IEC In=1250A to 690V, 50/60Hz AC Icu=55kA at 415V Icu=50kA at 500V Icu=42kA at 690V ETU320 electronic trip units li rotary codi …
-
3WL1106-2CB35-1AA2
Withdrawable circuit breaker without guide frame 3pole, size I, IEC In= 630A to 690V, AC50/60Hz Icu= 55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
-
3WL1106-2DG62-1AA2-Z C20
+C22 Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=630 A to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 27 LSING protection adjustabl …
-
3WL1106-2EB36-4GA4
Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection …
-
3WL1106-2FG78-4GG4-Z F02
Draw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=630 A to 690 V, 50/60 Hz AC Icu=55 kA at 500 V with connecting flange Overcurrent release ETU 45 LSING pr …
-